Complete Stud Welding RF weld studs are available in mild steel and stainless steel materials.
Material options and temperature limits are as follows:
304 SS – Temperature up to 1500 degrees F
310 SS – Temperature up to 1850 degrees F
330 SS – Temperature up to 2000 degrees F
601 Inconel – Temperature up to 2150 degrees F
RF studs are used to secure blanket insulation to furnaces. After the insulation is impaled over the RF studs, metal washers and or the ceramic cuplocks are installed and lock on the RF Stud to retain the insulation. The ceramic cuplock can be filled with refractory material or a ceramic plug.
Washers, ceramic cuplocks and cuplock plugs are sold separately. The RF stud and washer must be the same alloy.
For application, dimensional and in stock assistance, please contact your Complete Stud Welding representative.
A | B | C | D | E | F | G | H | I | J | |
---|---|---|---|---|---|---|---|---|---|---|
1
|
Stud Specifications | Standard Accessories | ||||||||
2
|
Thickness | Width | Length (Min.) |
Flash Dimensions | Ferrule | Foot | Grip | Chuck | ||
3
|
T | W | L | E | F | G | P/N | P/N | P/N | P/N |
4
|
0.125 | 0.25 | 1.5 | 0.3 | 0.109 | 0.218 | F025-R1 | B-1C | GC-037 | CR-CA |
To order or specify give: Stud Code, T x W x L Material and Quantity
Example: RF 0.125 x 0.25 x 5.25, (BW), 601 Inconel, 3000 pcs.
Specify (L) Length, on a Before Weld basis by indicating “BW”
or on an After Weld basis by indicating “AW.”
Product Images